- Tripp Lite Hot-swap PDU systems support live-replacement of standard UPS systems for maintenance with no interruption of connected server or networking loads.
- PDUBHV10 is universally compatible with any Tripp Lite or other brand of 200-240V UPS rated up to 1500VA with a C14 input cable option.
- 2U horizontal rack form factor compatible with 2 or 4 post racks.
- Supports space saving rear-post ing in the same rack space as many Tripp Lite Rack UPS systems (select installations, see manual).
- Pair of detachable PDU input cables connect to separate Utility and UPS power sources (2 C13-C14 interconnect cables included - user supplied alternate cabling supported).
- 2U rack hot-swap PDU enables live replacement of a standard UPS system without shutting down connected server and networking equipment.
- Manual transfer switch with lighted status indicators controls PDU output between Utility and UPS power sources.
- 8 C13 outlets support critical networking loads in both Utility and UPS operating modes.
- Separate PDU input cables connect to Utility and UPS power sources (pair of C13-C14 interconnect cables included, alternate input cordsets available).
Product Description
-------------------
Tripp Lite’s Hot-swap PDU systems enable
live-replacement of standard UPS systems for maintenance with no
interruption of connected server or networking loads. Dual input
power cables support PDU connection to separate Utility and UPS
power sources. Manual transfer switch with lighted status
indicators controls the source of power to connected equipment
between Utility and UPS. Set the switch to UPS during normal
operation and connected equipment will receive full-time
conditioned power from the UPS. Set the switch to Utility to
momentarily power connected equipment from the Utility line cord
and bypass the UPS while the UPS system is removed and replaced
with a fresh one. Once the new UPS is up and running with all
data and electrical connections restored, set the switch back to
the UPS setting to once again provide fully-conditioned UPS power
to connected equipment. PDUBHV10 is universally compatible with
any Tripp Lite or other brand of 200-240V UPS rated up to 1500VA
with a C14 input cable option. Pair of detachable PDU input
cables connect to separate Utility and UPS power sources (set of
2 C13-C14 interconnect cables included; user supplied alternate
cabling supported). 8 C13 outlets support critical networking
loads in both Utility and UPS operating modes. 2U rack
installation in 2 or 4 post racks with support for space saving
rear-post ing in the same rack space as your Tripp Lite
Rack UPS (select installations, see manual).
From the Manufacturer
---------------------
Do you need an economical way to upgrade your power protection
with add zero-downtime redundancy for mission-critical equipment?
Tripp Lite's PDUBHV10 Hot-Swap Power Distribution Unit is the
solution! The PDUBHV10 enables a standard 200-240V UPS system up
to 1500VA to be disconnected for maintenance or replacement with
no interruption of power to the connected load. This makes it
ideal for powering multiple loads in network, industrial and
similar applications that require continuous uptime. Featuring
eight outlets and a rugged all-metal housing, the PDUBHV10 is
suitable for 2U rack installation in 2- or 4-post racks and
rack enclosures.
Key Features
------------
Makes Any Compatible UPS Hot-Swappable
Click here for a larger image
Outlets
Click here for a larger image
Bypass Switch
Click here for a larger image
Makes Any Compatible UPS Hot-Swappable
--------------------------------------
The PDUBHV10 provides a cost-effective solution for applications
requiring zero-downtime power protection, but not large enough to
justify a full-featured hot-swappable UPS system. It makes any
200-240V UPS up to 1500VA with a C14 plug hot swappable, enabling
live replacement of a standard UPS without shutting down
connected equipment:
• Under normal conditions, conditioned power from the UPS is
transmitted to the connected load via the PDUBHV10.
• Should it become necessary to remove the UPS for maintenance
or replacement, the PDU's manual transfer switch is set to
BYPASS, disconnecting the UPS without interrupting power to the
load, which continues to receive unfiltered power directly
through the PDU's line cord. The UPS can then be removed.
• When the UPS is ready to be returned to service, it is
reconnected to the PDU and the manual transfer switch is set to
UPS, once more providing the load with conditioned power.
Front-panel status LEDs illuminate to indicate when the PDU is in
UPS and BYPASS modes.
Reliable IT Power Distribution
------------------------------
The PDUBHV10 is optimized for reliable distribution of alternate
waveform AC power from a UPS system in IT environments. It
provides eight C13 outlets for connected equipment, plus one
additional C19 outlet to accommodate the UPS plug. Dual
detachable 6-ft. C13 to C14 power cords connect the PDU to
utility power and to the UPS to draw power for the connected
load. Unfiltered electrical pass-through makes the PDUBHV10 ideal
for distributing alternate waveform UPS or generator power in
rack enclosures, network closets, and more.
Versatile Installation Options
------------------------------
The PDUBHV10 is easy to integrate with a wide range of data
center and network applications. It is suitable for 2U rack
installation in 2- or 4-post racks and rack enclosures. When
installed in a rack enclosure, it can be configured with Tripp
Lite's 4POSTRAILKIT for space-saving rear-post ing in the
same rack space as the supported rack UPS.
Technical Specifications
------------------------
Tripp Lite PDUBHV10 Hot-Swap Power Distribution Unit
----------------------------------------------------
Click here for a larger image
What's in the Box
-----------------
* PDUBHV10 Hot-Swap PDU
* 2 x Detachable 6-ft. C13 to C14 Power Cords
* ing Hardware
* Owner's Manual with Warranty Information
Protect, Power, Organize and Control with Tripp Lite
----------------------------------------------------
Tripp Lite UPS Systems and accessories are available with a wide
range of features to provide reliable, cost-effective power
protection and connectivity solutions for all electronics.
PDUMH15HVNET Switched/Metered Power Distribution Unit
-----------------------------------------------------
Switched/metered 1U rack PDU with 8 x C13 outlets and
detachable 12-ft. power cord with C14 plug. The PDUMH15HVNET
provides 15A 200/208/230/240V capacity, remote power management
and individual outlet control via a secure web/network interface,
a digital amp meter for on-site monitoring of total PDU load, and
sequential outlet power-on capability to prevent inrush-related
equipment interaction on startup. Switchless, circuit
breaker-free design prevents accidental shut-off. 2-year
warranty.
PDUBHV20 Hot-Swap Power Distribution Unit
-----------------------------------------
Hot-swap 2U rack PDU with 6 x C13 and 2 x C19 outlets for
connected equipment and dual detachable 6-ft. power cords with
C20 plugs. The PDUBHV20 makes any compatible UPS system
hot-swappable. It enables a standard 200-240V UPS from 2000VA to
3000VA to be disconnected for maintenance or replacement with no
interruption of power to the connected load. 2-year warranty.
SUINT1500RTXL2Ua SmartOnline™ UPS System
----------------------------------------
True on-line operation with pure sine wave output and zero
transfer time provides the highest level of protection for
mission-critical equipment. The SUINT1500RTXL2Ua features
1500VA/1200W power capacity, selectable 200/208/220/230/240V
input/output and 6 outlets arranged in 2 individually
controllable load banks. One USB port and one DB9 port with
included cables and PowerAlert power management software provide
complete power network monitoring and control. The
SUINT2200RTXL2Ua supports connected equipment for 12 minutes
during power failures at a half load of 600 watts and runtime is
expandable with optional external battery packs. 2-year warranty.
B020-U08-19-K NetDirector™ Console KVM Switch
---------------------------------------------
Controls an entire network in just 1U of rack space. The
B020-U08-19-K combines a keyboard, 19-in. LCD screen, touch pad,
numeric keypad, and 8-port KVM switch in a 1U slide-out unit. It
is USB or PS/2 compatible with 8 included PS2/USB Combo Cable
Kits to connect switch to servers. Controls up to 504 servers by
daisy-chaining additional KVMs. Includes two front-ed USB
ports: one for attachment of a separate USB mouse and one to
connect USB peripherals (flash drive, external hard drive, etc.)
that can be shared between connected servers.
SRCOOL12K Self-Contained Portable Air Conditioning Unit
-------------------------------------------------------
Compact, portable air conditioning unit is ideal for wiring
closets and other space-critical locations where facility air
conditioning can't reach. 12,000 BTU of cooling power. Connects
to a standard 5-15R receptacle; no adapter required. Uses
EPA-compliant R410a refrigerant. Standard louvered vent for
general room cooling; ducted vent to direct cold air where
needed. Requires no floor drain or water collection tank. 1-year
warranty.
SR42UB SmartRack™ Enclosure
---------------------------
Premium 42U rack enclosure organizes and secures all standard
rack equipment. The SR42UB features locking, removable,
reversible front and rear doors; locking, removable side panels
keyed alike with doors; 4 interior vertical posts with unthreaded
square-hole openings; preinstalled casters and leveling feet; and
3000-lb. stationary/2250-lb. rolling load capacity. The SR42UB
ships fully assembled and comes with a 5-year repair/replacement
warranty. A full range of rack accessories is also
available.